1 .. 23 24 25 26 27 28 29 30 31 32 33 .. 46
Página 28
Impreso Nº.
 PC158-500 Rev
.
 1 (08/06)
CAP
ACID
ADES FRIGORÍFICAS - MODELOS SE ENFRIAMIENTO DE GLICOL
Temp
Salida
del
Agua
o
C
kWo
kWci
EER
kWo
kWci
EER
kWo
kWci
EER
kWo
kWci
EER
kWo
kWci
EER
4
172.6
43.6
3.4
164.4
48.0
3.0
155.6
53.2
2.6
147.2
59.2
2.2
138.4
67.6
1.9
2
160.4
43.1
3.2
152.8
47.4
2.8
144.7
52.5
2.4
136.6
58.4
2.1
128.1
66.0
1.8
0
148.4
42.6
3.0
141.3
46.8
2.6
134.1
51.8
2.3
126.2
57.6
2.0
118.0
64.4
1.7
-2
136.2
41.9
2.8
129.7
46.1
2.4
122.9
50.9
2.1
115.7
56.7
1.8
-4
123.1
41.1
2.6
117.1
45.3
2.2
110.9
50.1
1.9
104.4
55.7
1.7
-6
110.5
40.4
2.3
105.1
44.6
2.0
99.4
49.2
1.8
93.6
54.8
1.5
4
196.8
51.6
3.4
187.2
56.8
2.9
177.0
62.8
2.5
166.4
69.2
2.2
155.0
78.6
1.8
2
182.9
50.8
3.2
173.8
56.0
2.8
164.2
61.8
2.4
154.6
68.2
2.1
0
169.1
50.0
3.0
160.7
55.2
2.6
151.7
60.8
2.2
143.1
67.2
1.9
-2
155.3
49.1
2.8
147.4
54.0
2.4
139.1
59.6
2.1
131.0
66.0
1.8
-4
140.3
48.1
2.5
133.1
52.8
2.2
125.5
58.4
1.9
118.0
64.8
1.6
-6
126.0
47.2
2.3
119.3
51.6
2.0
112.5
57.2
1.8
105.7
63.6
1.5
4
218.0
61.2
3.2
207.4
68.0
2.8
195.2
75.6
2.4
182.0
83.6
2.0
2
203.9
60.2
3.0
194.1
66.8
2.6
182.6
74.3
2.2
169.7
82.3
1.9
0
190.1
59.2
2.9
181.1
65.6
2.5
170.1
73.0
2.1
157.6
81.0
1.8
-2
174.6
57.9
2.7
166.4
64.3
2.3
156.7
71.6
2.0
145.5
79.6
1.7
-4
157.9
56.7
2.5
150.5
62.9
2.2
142.1
70.2
1.8
-6
141.8
55.4
2.3
135.4
61.6
2.0
128.2
68.8
1.7
4
233.0
67.6
3.1
222.0
74.4
2.7
210.0
82.0
2.4
198.0
91.2
2.0
2
217.3
66.4
3.0
206.6
73.2
2.6
195.2
80.6
2.2
183.2
89.6
1.9
0
201.9
65.2
2.8
191.5
72.0
2.4
180.7
79.2
2.1
168.6
88.0
1.8
-2
185.6
63.9
2.6
176.4
70.6
2.3
165.9
77.7
2.0
-4
168.0
62.5
2.4
160.0
69.2
2.1
149.9
76.3
1.8
-6
151.2
61.2
2.2
144.4
67.8
1.9
134.6
74.8
1.6
4
273.8
76.8
3.3
260.4
84.8
2.8
247.0
93.5
2.5
231.6
104.2
2.1
2
255.0
75.6
3.1
242.5
83.4
2.7
229.8
92.1
2.3
215.6
102.2
2.0
0
236.6
74.4
2.9
224.8
82.0
2.5
212.9
90.6
2.2
199.8
100.2
1.9
-2
217.4
73.1
2.7
206.6
80.6
2.4
195.3
89.0
2.0
-4
196.7
71.8
2.5
186.9
79.3
2.2
176.5
87.4
1.9
-6
176.9
70.5
2.3
168.0
77.9
2.0
158.4
85.8
1.7
4
307.6
90.0
3.2
292.4
99.2
2.8
276.8
109.6
2.4
258.0
122.8
2.0
2
286.5
88.4
3.0
272.4
97.4
2.6
257.8
107.7
2.2
241.1
120.0
1.9
0
265.8
86.8
2.8
252.8
95.6
2.5
239.1
105.8
2.1
224.4
117.2
1.8
-2
244.5
84.9
2.7
232.4
93.7
2.3
219.5
103.5
2.0
-4
221.5
83.1
2.5
210.4
91.7
2.1
198.4
101.1
1.8
-6
199.4
81.2
2.3
189.4
89.8
2.0
178.2
98.8
1.7
4
344.0
91.6
3.4
327.6
101.0
2.9
310.0
111.4
2.5
291.0
123.6
2.2
273.0
138.8
1.8
2
320.3
90.1
3.2
304.9
99.4
2.8
288.5
109.6
2.4
271.1
121.5
2.1
252.9
136.1
1.7
0
296.9
88.5
3.0
282.6
97.7
2.6
267.3
107.8
2.3
251.5
119.3
1.9
-2
272.5
86.8
2.8
259.3
95.9
2.4
245.4
105.9
2.1
230.5
117.3
1.8
-4
246.2
85.1
2.6
234.1
94.2
2.2
221.7
104.1
1.9
207.9
115.3
1.7
-6
221.0
83.4
2.4
210.1
92.4
2.0
199.1
102.2
1.8
4
362.0
99.2
3.3
344.0
109.6
2.9
325.0
120.8
2.5
305.0
134.0
2.1
286.0
150.0
1.8
2
337.0
97.7
3.1
320.0
107.9
2.7
302.2
119.0
2.3
283.8
131.8
2.0
263.3
147.4
1.7
0
312.4
96.2
2.9
296.4
106.2
2.5
279.9
117.2
2.2
263.0
129.6
1.9
-2
286.5
94.4
2.7
271.7
104.3
2.4
256.8
115.1
2.0
241.0
127.6
1.7
-4
258.5
92.6
2.5
245.3
102.3
2.2
232.0
113.1
1.9
217.1
125.4
1.6
-6
231.8
90.8
2.3
220.0
100.4
2.0
208.3
111.0
1.7
4
410.5
114.8
3.3
390.8
126.4
2.9
369.8
139.4
2.5
347.2
155.0
2.1
2
381.9
112.9
3.1
363.8
124.4
2.7
343.9
137.3
2.3
322.8
152.2
2.0
0
353.8
111.0
2.9
337.3
122.4
2.5
318.5
135.2
2.2
298.9
149.3
1.9
-2
324.6
108.7
2.7
309.2
120.0
2.4
292.1
132.7
2.0
-4
293.3
106.5
2.5
279.1
117.6
2.2
263.7
130.1
1.9
-6
263.3
104.2
2.3
250.2
115.2
2.0
236.6
127.6
1.7
4
452.4
133.6
3.1
430.6
146.8
2.7
407.6
162.0
2.4
382.0
180.8
2.0
2
421.4
131.0
3.0
401.4
144.4
2.6
379.5
159.4
2.2
355.9
177.0
1.9
0
391.0
128.4
2.8
372.8
142.0
2.4
351.8
156.8
2.1
330.3
173.2
1.8
-2
359.0
125.6
2.6
342.0
138.9
2.3
322.9
153.6
2.0
-4
324.6
122.8
2.4
308.9
135.9
2.1
291.7
150.4
1.8
-6
291.6
120.0
2.2
277.2
132.8
1.9
261.9
147.2
1.7
Notas:
kWo
=
Capacidad
frigorífica
a
plena
carga.
kWci
=
Potencia
absorbida
de
todos
los
compresores
(kW).
EER
=
Coef.
de
Rendimiento
Energético
e
incluye
compresores
y
ventiladores.
D
a
t
o
s
e
n
b
a
s
e
a
5
°
C
diferencia
de
temp.
del
líquido
frío
y
un
factor
de
ensuciamiento
0,044m
²
-
°
C/kW.
Equipos
con
Ventiladores
de
Dos
Velocidades:
Los
valores
que
indican
las
tablas
son
con
los
ventiladores
funcionando
a
velocidad
normal.
Carga
parcial
con
el
compresor
mayor
funcionando
por
circuito
Los
ventiladores
funcionarán
a
velocidad
lenta
cuando
la
temperaura
ambiente
sea
de
27°C
o
inferior.
Para
capacidades
frigoríficas
y
potencia
absorbida
del
compresor
(kW)
con
el
ventilador
funcionando
a
velocidad
lenta,
a
25°C
de
temp.
ambiente,
véanse
los
datos
sobre
plantas
enfriadoras
de
bajo
nivel
sonoro.
Modelo
YLAE
0190SE
YLAE
0255SE
YLAE
0305SE
YLAE
0215SE
YLAE
0235SE
YLAE
0490SE
YLAE
0395SE
YLAE
0450SE
YLAE
0330SE
YLAE
0375
SE
Temperatura
de
Entrada
del
Aire
en
la
Batería
Condensadora
o
C
25
30
35
40
45